Service Ports/Access Valves
The sealing cap is the primary seal for the service ports. The cap contains an O-ring gasket that provides a leak-free seal. Install the cap tightly for leak-free sealing. The following conditions will cause a refrigerant loss:- A loose cap
- A missing cap
- An incorrect cap
Use J 42220 or J 39400-A in order to test the service ports and sealing caps for leaks.
To prevent a false diagnosis, thoroughly clean any residual dye from the service port or sealing cap with a rag and the approved fluorescent dye cleaner J 43872.