Air Recirculation Malfunction
TEST DESCRIPTIONSteps 1-8:
Steps 9-11:
The numbers below refer to the step numbers on the diagnostic table.
5. There are 2 ignition 3 voltage circuits at the HVAC control module. Test the circuit that is not the supply voltage circuit for the blower motor switch.