Refrigerant Pressure Sensor / Switch: Service and Repair
AIR CONDITIONING (A/C) REFRIGERANT PRESSURE SENSOR REPLACEMENTTOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Remove the air cleaner assembly.
2. Disconnect the electrical connector from the A/C refrigerant pressure sensor.
3. Remove the A/C refrigerant pressure sensor from the condenser tube.
INSTALLATION PROCEDURE
1. Replace the O-ring seal for the A/C refrigerant pressure sensor.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the A/C refrigerant pressure sensor to the condenser tube.
Tighten
Tighten the sensor to 4.7 N.m (41 lb in).
3. Connect the electrical connector to the A/C refrigerant pressure sensor.
4. Install the air cleaner assembly.
5. Leak test the fittings of the component using J 39400-A.