Do you have access to Mitchell1 Prodemand? If you are willing to share user/password (we can pay $250), please get in contact with us ASAP: email operation-charm [[at]] tuta.io or click to submit anonymously. (I know, we said we wouldn't ask any more...but it's important!)
Blower Motor Processor Replacement - Auxiliary
REMOVAL PROCEDURE1. Remove the right rear quarter trim panel.
2. Remove the HVAC module-auxiliary.
3. Disconnect the electrical connector from the blower motor processor (1).
4. Remove the retaining screws from the blower motor processor (1).
5. Remove the blower motor processor (1) from the HVAC module (2).
INSTALLATION PROCEDURE
1. Install the blower motor processor (1) to the HVAC module (2).
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the retaining screws to the blower motor processor (1).
Tighten
Tighten the screws to 1.9 N.m (17 lb in).
3. Install the HVAC module-auxiliary.
4. Connect the electrical connector to the blower motor processor (1).
5. Install the right rear quarter trim panel.