Fuel Injector Circuit Diagnosis
CIRCUIT DESCRIPTIONThe control module enables the appropriate fuel injector on the intake stroke for each cylinder. An ignition 1 voltage is supplied directly to the fuel injectors. The control module controls each fuel injector by grounding the control circuit via a solid state device called a driver.
DIAGNOSTIC AIDS
- Monitoring the fuel injector circuit status with a scan tool, while moving the fuel injector harness, may help to isolate an intermittent condition.
- Performing the Fuel Injector Coil Test may help isolate an intermittent condition. Refer to Fuel Injector Coil Test. Component Tests and General Diagnostics
- For an intermittent condition, refer to Intermittent Conditions. Diagnostic Strategies
TEST DESCRIPTION
Steps 1-5:
Steps 6-10:
Steps 11-14:
The numbers below refer to the step numbers on the diagnostic table.
4. This step tests for a short to ground on the ignition 1 voltage supply circuit of the fuel injector.
5. This step tests for a short to a PCM ground on the ignition 1 voltage supply circuit of the fuel injector.
6. This step tests for an open ignition 1 voltage supply circuit between the fuel injector fuse and the multi-way connector.
7. This step tests for an open or high resistance between the multi-way connector and the fuel injectors.