Inflatable Restraint Instrument Panel Module Replacement
REMOVAL PROCEDURE1. Disable the SIR system. Refer to SIR Disabling and Enabling Zone 5.
CAUTION:
- Refer to SIR Inflator Module Handling and Storage Caution in Service Precautions.
- Refer to SIR Caution in Service Precautions.
2. Remove the I/P upper trim pad.
3. Remove the connector position assurance (CPA) from the I/P module harness connector.
4. Disconnect the pigtail connector from the I/P module.
5. Remove the mounting fasteners (3) from the I/P module.
6. Remove the I/P module (1) from the bracket (2).
7. Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to Inflator Module Handling and Scrapping.
INSTALLATION PROCEDURE
1. Install the I/P module (1) to the bracket (2).
2. Install the I/P module mounting fasteners (3).
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the fasteners to 10 N.m (89 lb in).
3. Connect the pigtail connector to the I/P module.
4. Install the CPA to the harness connector on the I/P module.
5. Install the I/P upper trim pad.
6. Enable the SIR system. Refer to SIR Disabling and Enabling Zone 5.