Operation CHARM: Car repair manuals for everyone.

Recirculation Door (Delphi)

RECIRCULATION DOOR REPLACEMENT (DELPHI)

REMOVAL PROCEDURE
1. Remove the HVAC module assembly.




2. Disconnect the recirculation actuator electrical connection (1).




3. Remove the recirculation actuator mounting screws.




4. Remove the recirculation actuator.
5. Remove the recirculation door.

INSTALLATION PROCEDURE




1. Install the recirculation door.
2. Install the recirculation actuator.

NOTE: Refer to Fastener Notice in Service Precautions.




3. Install the recirculation actuator mounting screws.

Tighten
Tighten the screws to 1.9 N.m (17 lb in).




4. Connect the recirculation actuator electrical connection (1).
5. Install the HVAC module assembly.