Air Delivery
AIR DELIVERY DESCRIPTION AND OPERATION
The air delivery controls are divided into four areas.
- HVAC Control Components
- Air Speed
- Air Delivery
- Recirculation Operation
HVAC CONTROL COMPONENTS
HVAC Control Module
The HVAC control module is a class 2 device that interfaces between the operator and the HVAC system to maintain air temperature and distribution settings. The battery positive voltage circuit provides power that the control module uses for keep alive memory (KAM). If the battery positive voltage circuit loses power, all HVAC DTCs and settings will be erased from KAM. The body control module (BCM), which is the vehicle mode master, provides a device on signal. The control module supports the features.
Mode Actuator
The mode actuator is a 5-wire bi-directional electric motor that incorporates a feedback potentiometer. Ignition 3 voltage, low reference, control, 5-volt reference and position signal circuits enable the actuator to operate. The control circuit uses either a 0, 2.5 or 5-volt signal to command the actuator movement. When the actuator is at rest, the control circuit value is 2.5 volts. A 0 or 5-volt control signal commands the actuator movement in opposite directions. When the actuator shaft rotates, the potentiometer's adjustable contact changes the door position signal between 0-5 volts.
The HVAC control module uses a range of 0-255 counts to index the actuator position. The door position signal voltage is converted to a 0-255 count range. When the module sets a commanded, or targeted value, the control signal is changed to either 0 or 5 volts depending upon the direction that the actuator needs to rotate to reach the commanded value. As the actuator shaft rotates the changing position signal is sent to the module. Once the position signal and the commanded value are the same, the module changes the control signal to 2.5 volts.
Air Speed
The blower motor circulates air through the vehicle's interior. The vehicle operator determines the blower motor's speed when the driver places the blower switch in one of 5 blower speeds. The blower motor will always operate in any switch position other than OFF, as long as the ignition switch is in the RUN position. The blower motor and mode switches are located within the HVAC control module. The blower motor OFF input is connected in series with the HVAC control module by the off blower motor control circuit.
Depending upon the selected speed, power is provided to the blower motor from either the ignition 3 voltage or battery positive voltage circuits from the fuse block. The battery positive voltage circuit only provides power when the High blower switch position is selected. Power and ground are provided to the HVAC control module by the ignition 3 voltage and the ground circuits.
Low Blower Speed
When the Low 1 blower speed is selected, the HVAC control module applies voltage to the blower motor resistor assembly through the low blower motor control circuit. Voltage is divided between 4 series resistors, a blower relay, and the blower motor to achieve the desired blower speed. The blower motor is grounded through the ground circuit.
Medium Blower Speeds
When the Medium 1 blower speed is selected, the HVAC control module applies voltage to the blower motor resistor assembly through the medium 1 blower motor control circuit. Voltage is divided between 3 series resistors, a blower relay, and the blower motor to achieve the desired blower speed. The blower motor is grounded through the ground circuit.
When the Medium 2 blower speed is selected, the HVAC control module applies voltage to the blower motor resistor assembly through the medium 2 blower motor control circuit. Voltage is divided between 2 series resistors, a blower relay, and the blower motor to achieve the desired blower speed. The blower motor is grounded through the ground circuit.
When the Medium 3 blower speed is selected, the HVAC control module applies voltage to the blower motor resistor assembly through the medium 3 blower motor control circuit. Voltage is divided between a series resistor, a blower relay, and the blower motor to achieve the desired blower speed. The blower motor is grounded through the ground circuit.
High Blower Speed
When the High blower speed is selected, the HVAC control module applies voltage to the blower motor resistor assembly through the high blower motor control circuit. The voltage energizes the blower relay, causing the blower motor to be connected directly to the battery positive voltage circuit. The blower motor and blower motor relay are grounded through the ground circuit.
Off
When the OFF position is selected, the HVAC control module applies voltage to the fan off input within the HVAC control module through the off blower motor control circuit. When the HVAC control module receives this input, any A/C request will be cancelled and the A/C request LED will turn off. Fresh air will still be brought in from the outside, but the LED indicator on the switch will not illuminate.
Recirculation Mode
When the recirculation switch is pressed, a signal is sent from the HVAC control module to the recirculation actuator through the recirculation door control circuit. When the logic receives the signal, the recirculation actuator moves into the recirculation mode. This brings air from inside the vehicle instead of fresh air from the outside. Power and ground are provided to the recirculation actuator by the ignition 3 voltage and ground circuit. Recirculation is not available when the HVAC control module is in the defrost position. The recirculation mode will stay on and the LED will illuminate until a non-recirculation mode is selected.
Air Delivery
The HVAC control module controls the mode actuator in order to distribute airflow to a desired outlet. The mode switch provides the vehicle operator with the ability to override the automatic setting. When the mode door is moved to the defrost position, the A/C compressor clutch engages and the recirculation actuator will be moved to the outside air position. Regardless of the mode setting, a small amount of air will be diverted to the defrost ducts to reduce windshield fogging.
Mode Actuator
The mode actuator is an electronic stepper motor with feedback potentiometers. The HVAC control module sends different signals to the mode door actuator through the mode door control circuit. Zero volts drives the actuator in one direction while 5 volts moves the actuator in the opposite direction. When the actuator receives 2.5 volts, the actuator rotation stops. A 5-volt reference signal is sent out over the 5-volt reference circuit to the mode actuator. When you select a desired mode setting, logic determines the value of the mode actuator signals. The HVAC control module's software uses this reference voltage in order to determine the position of the mode actuator through the mode door position signal circuit. The motor moves the mode door to the desired position.
Front Defrost
When you select defrost, the A/C compressor is activated. The A/C compressor clutch will engage when ambient temperatures are above 3°C (38°F). The blower motor will be activated, regardless of the coolant temperature. The rear window defogger does not affect the HVAC system.
Recirculation Operation
Recirculation Actuator
The HVAC control module controls the air intake through the recirculation actuator. Recirculation is not available when the mode is in defrost. When the mode is in defog, Recirculation will only be available for 10 minutes. The operator must activate the blower for Recirculation operation. The A/C high-pressure recirculation switch can cause the HVAC system to recirculate air. If the recirculation switch is pressed into the ON position when the mode switch is in an unavailable mode position, then the recirculation switch LED will flash 3 times. When the high side pressure reaches 2206-2620 Kpa (320-380 psi), the PCM will place the HVAC system in recirculation mode. The high side pressure is lowered when the inside air cools the refrigerant within the A/C evaporator. When the high-side pressure reaches 1447-1861 Kpa (210-270 psi), the PCM will place the HVAC system out of recirculation mode.