AIR TEMPERATURE DOOR REPLACEMENT - LEFT (VISTEON)

REMOVAL PROCEDURE
1. Remove the HVAC module. Service and Repair




2. Disconnect the electrical connector (3) from the mode actuator (4).
3. Remove the screws from the mode actuator (4).
4. Remove the mode actuator (4) from the HVAC module (1).
5. Remove the wiring harness from the air distribution housing (1).




6. Remove the screws from the air distribution housing (1).
7. Remove the air distribution housing (1) from the HVAC module (2).




8. Remove the screws from the upper recirculation housing (1).
9. Remove the upper recirculation housing (1) from the HVAC module (2).




10. Remove the screws from the lower recirculation housing (1).
11. Remove the lower recirculation housing (1) from the HVAC module (2).




12. Remove the wiring harness from the HVAC module.
13. Remove the screws from the HVAC module.
14. Remove the upper HVAC module case (1) from the lower HVAC module case (2).




15. Remove the HVAC module chamber plate (1) from the lower HVAC module case (3).
16. Remove the left temperature door (2) from the lower HVAC module case (3).

INSTALLATION PROCEDURE




1. Install the left temperature door (2) to the lower HVAC module case (3).
2. Install the HVAC module chamber plate (1) to the lower HVAC module case (3).
3. Install the upper HVAC module case (1) to the lower HVAC module case (2).
4. Install the screws to the HVAC module.

NOTE: Refer to Fastener Notice in Service Precautions.

Tighten the screws to 2 N.m (18 lb in).




5. Install the wiring harness to the HVAC module.
6. Install the lower recirculation housing (1) to the HVAC module (2).




7. Install the screws to the lower recirculation housing (1).

Tighten the screws to 2 N.m (18 lb in).

8. Install the upper recirculation housing (1) to the HVAC module (2).




9. Install the screws to the upper recirculation housing (1).

Tighten the screws to 2 N.m (18 lb in).




10. Install the air distribution housing (1) to the HVAC module (2).
11. Install the screws to the air distribution housing (1).

Tighten the screws to 2 N.m (18 lb in).

12. Install the wiring harness to the air distribution housing (1).
13. Install the mode actuator (4) to the HVAC module (1).
14. Install the screws to the mode actuator (4).

Tighten the screws to 2 N.m (18 lb in).




15. Connect the electrical connector (3) to the mode actuator (4).
16. Install the HVAC module.