Blower Motor Control Processor Replacement
BLOWER MOTOR CONTROL PROCESSOR REPLACEMENT
REMOVAL PROCEDURE
1. Remove the right closeout panel.
2. Disconnect the electrical connector from the blower motor.
3. Disconnect the electrical connector (3) from the blower motor control processor (1).
4. Remove the blower motor control processor mounting screws (2).
5. Remove the blower motor control processor (1).
INSTALLATION PROCEDURE
1. Install the blower motor control processor (1).
2. Install the blower motor control processor mounting screws (2).
Tighten the screws to 1.9 N.m (17 lb in).
NOTE: Refer to Fastener Notice in Service Precautions.
3. Connect the electrical connector (3) to the blower motor control processor (1).
4. Connect the electrical connector to the blower motor.
5. Install the right closeout panel.