Generator Bracket Replacement
GENERATOR BRACKET REPLACEMENT
REMOVAL PROCEDURE
CAUTION: Refer to Battery Disconnect Caution in Service Precautions.
1. Disconnect the negative battery cable.
2. Remove the air cleaner.
3. Remove the drive belt.
4. Remove the upper fan shroud.
5. Remove the electrical harness clip bolts.
6. Disconnect the generator electrical connector (1).
7. Remove the positive battery cable from the generator, perform the following:
1. Slide the boot (3) down to access the terminal stud.
2. Remove the positive cable nut (2).
3. Remove the positive cable.
8. Remove the drive belt tensioner bolt.
9. Remove the generator mounting bracket bolts.
10. Remove the generator mounting bracket.
11. If necessary, remove the idler pulleys.
INSTALLATION PROCEDURE
1. If necessary, install the idler pulleys.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the bolts to 50 N.m (37 lb ft).
2. Install the generator mounting bracket.
3. Install the generator mounting bracket bolts.
Tighten the bolts to 50 N.m (37 lb ft).
4. Install the drive belt tensioner bolt.
Tighten the bolt to 50 N.m (37 lb ft).
5. Install the positive battery cable to the generator, perform the following:
1. Install the positive cable.
2. Install the positive cable nut (2).
Tighten the nut to 9 N.m (80 lb in).
3. Slide the boot (3) up to cover the terminal stud.
6. Connect the generator electrical connector (1).
7. Install the electrical harness clip bolts.
Tighten the bolts to 10 N.m (89 lb in).
8. Install the upper fan shroud.
9. Install the drive belt.
10. Install the air cleaner.
11. Connect the negative battery cable.