Generator Replacement
GENERATOR REPLACEMENT
REMOVAL PROCEDURE
CAUTION: Refer to Battery Disconnect Caution in Service Precautions.
1. Disconnect the negative battery cable.
2. Disconnect the generator electrical connector (1).
3. Remove the drive belt.
4. Remove the positive battery cable from the generator, perform the following:
1. Slide the boot (3) down to access the terminal stud.
2. Remove the positive cable nut (2).
3. Remove the positive cable.
5. Remove the generator bolts (1).
6. Remove the generator (2).
INSTALLATION PROCEDURE
1. Install the generator (2).
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the generator bolts (1).
Tighten the bolts to 50 N.m (37 lb ft).
3. Install the positive battery cable to the generator, perform the following:
1. Install the positive cable.
2. Install the positive cable nut (2).
Tighten the nut to 9 N.m (80 lb in).
3. Slide the boot (3) up to cover the terminal stud.
4. Install the drive belt.
5. Connect the generator electrical connector (1).
6. Connect the negative battery cable.