Operation CHARM: Car repair manuals for everyone.

P1A62




DTC P1A62

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview) provides an overview of each diagnostic category.

DTC Descriptor
DTC P1A62
- Starter/Generator Control Module Torque Delivered Performance

Circuit/System Description

The starter/generator control module (SGCM) monitors the internal torque value and compares it to the motor generator unit (MGU) delivered torque value. If the delivered torque is not within tolerance, the DTC will set.

Conditions for Running the DTC

The engine is running.

Conditions for Setting the DTC

Torque error is greater than 10 Nm for 1 second.

Action Taken When the DTC Sets

Delivered torque (CAN data) = command torque.

Conditions for Clearing the DTC

Normal range for 1 second

Reference Information
Schematic Reference

Hybrid Controls Schematics (Electrical Diagrams)
Connector End View Reference

Component Connector End Views (Connector Views)
Description and Operation

Starter/Generator Description and Operation (Description and Operation)
Electrical Information Reference

* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)

Scan Tool Reference

Control Module References (Programming and Relearning) for scan tool information

Circuit/System Testing

1. Disconnect harness connector X2 from the SGCM. Refer to Generator Control Module Replacement (Generator Control Module Replacement).
2. Test for 5-100 ohms between terminals 9 and 12.

If within the specified range, replace the SGCM.

3. Disconnect the X1 connector at the MGU. Refer to Generator with Starter Replacement (Service and Repair)
4. Test for less than 1 ohm between SGCM connector harness terminal 12 and the MGU connector harness terminal A.

If greater than the specified range, test the circuit for open/high resistance.

5. Test for less than 1 ohm between SGCM connector harness terminal 9 and the MGU X1 connector harness terminal C.

If greater than the specified range, test the circuit for open/high resistance.

6. If both circuits test normal, replace the MGU.

Repair Instructions

Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.

* Generator with Starter Replacement (Service and Repair)
* Control Module References (Programming and Relearning) for SGCM replacement, setup, and programming