9. Torque Converter End Play Inspection
Torque Converter End Play Inspection
Tools Required
* J 43764 Torque Converter End Play Gauge
* J 5959 Dial Indicator Clamp and Adjuster
* J 7872 Magnetic Base Dial Indicator
1. Position the torque converter (3) on the work table so that the pump hub is facing up.
2. Install J 43764 (2) into the torque converter hub.
3. Hold J 43764 (2) in the converter hub and rotate the center screw until J 43764 is locked into the converter hub. Do not over tighten J 43764 .
4. Assemble the following tools and install the tools onto the torque converter as shown:
* J 5959 (1)
* Extension rod (7)
* Clamp (6)
* J 7872 (4)
* Adaptor rod (5)
5. Adjust the clamp (6) so that the dial indicator (1) firmly contacts the top of J 43764 (2).
6. Set the J 5959 (1) to read zero.
7. Lift J 43764 (2) upward as far as possible.
8. Read the J 5959 (1) to determine torque converter end play.
9. Compare the measured end play with the torque converter end play specifications. Refer to End Play Specifications (End Play Specifications).
10. If the measured torque converter end play exceeds the value listed, replace the torque converter.
11. Remove the J tools from the converter housing.