Mode Valve Lever Replacement (Left Hand Drive)
Mode Valve Lever Replacement (Left Hand Drive)
Removal Procedure
1. Remove instrument panel assembly. Refer to Instrument Panel Assembly Replacement (Instrument Panel Assembly Replacement).
2. Remove instrument panel wiring harness (2) from instrument panel tie bar (1).
Disconnect electrical connectors.
3. Remove instrument panel tie bar (2).
* Remove 4 instrument panel tie bar bolts (3, 4).
* Remove 2 instrument panel tie bar nuts (1).
4. Remove mode control cam (1).
5. Remove 2 mode valve lever (1).
Installation Procedure
1. Remove 2 mode valve lever (1).
Note: The mode valve levers have to be fitted to the according mode valve gears in figured position. The ventilation dampers have to be in middle position.
2. Make sure that mode valve gears of mode valve levers (1) are fitted as shown in graphic above.
Note: The mode control cam can only be fitted in one position.
3. Install mode control cam (1).
Caution: Refer to Fastener Caution (Fastener Caution).
4. Install instrument panel tie bar (2).
* Install 4 instrument panel tie bar bolts (3, 4) and tighten to 22 Nm (17 lb ft).
* Install 2 instrument panel tie bar nuts (1) and tighten to 9 Nm (80 lb in).
5. Install instrument panel wiring harness (2) from instrument panel tie bar (1).
Connect electrical connectors.
6. Install instrument panel assembly. Refer to Instrument Panel Assembly Replacement (Instrument Panel Assembly Replacement).