Service Port HVAC: Service and Repair
Service Ports Replacement
Tools Required
* J 39400-A Halogen Leak Detector
* J 46246 Valve Core Removal Tool
Removal Procedure
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging (Refrigerant Recovery and Recharging).
2. Use J 46246 or equivalent to remove the valve core.
Installation Procedure
1. Use J 46246 or equivalent to install and tighten the valve core.
2. Evacuate and charge the A/C system. Refer to Refrigerant Recovery and Recharging (Refrigerant Recovery and Recharging).
Important: To prevent loss of refrigerant charge, tighten the cap. Replace the cap if the seal is missing or damaged.
3. Test the affected A/C fittings for leaks using J 39400-A .