Malfunction Indicator Lamp: Testing and Inspection
Malfunction Indicator Lamp (MIL) Diagnosis
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.
Circuit/System Description
Ignition voltage is supplied to the malfunction indicator lamp (MIL). The engine control module (ECM) turns the MIL ON by grounding the MIL control circuit.
Reference Information
Schematic Reference
Engine Controls Schematics [1][2]Electrical Diagrams
Connector End View Reference
Component Connector End Views Fuel Pump and Level Sensor Assembly
Electrical Information Reference
* Circuit Testing Circuit Testing
* Connector Repairs Connector Repairs
* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections
* Wiring Repairs Wiring Repairs
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Scan Tool Reference
Control Module References Control Module References for scan tool information
Circuit/System Verification
1. Ignition ON, observe the DTC information with a scan tool. Verify that DTCs U0073, U0100, or U0155 are not set.
• If any of the DTCs are set, refer to Diagnostic Trouble Code (DTC) List - Vehicle Diagnostic Trouble Code (DTC) List - Vehicle.
2. Ignition ON, the MIL should turn ON and OFF when commanded with a scan tool.
Circuit/System Testing
Ignition ON, verify that the P16 Instrument Cluster warning indicators are illuminated.
If the P16 Instrument Cluster warning indicators are not illuminated, test the P16 Instrument Cluster ignition circuit terminal 31 for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, replace the P16 Instrument Cluster.
Repair Instructions
Perform the Diagnostic Repair Verification Verification Tests after completing the diagnostic procedure.
* Instrument Cluster Replacement Service and Repair
* Control Module References Control Module References for ECM replacement, programming and setup