DA-6 Compressor
1. Remove compressor2. Drain oil
3. Measure, replace same amount of new oil plus 0.085 kg. (3 ounces) to compensate for that retained by the original accumulator desiccant. If no oil can be drained from old accumulator, add 0.057 kg. (2 ounces) new oil to the new accumulator.