1989-93 Tracker
1. Using the Service Manual, remove the following components in the order given:a. Receiver/dryer.
b. Evaporator to compressor (suction) pipe.
c. Compressor to condenser (compressor discharge) pipe.
d. Joint service connector on compressor (to be reinstalled).
e. Compressor (only if being replaced).
2. Using the Service Manual, install the following components in the order given. Be sure to use new 0-rings whenever a refrigerant connection has been disconnected.
a. Compressor (if being replaced).
b. High and low side adapter fittings (see Step 3 of the Retrofit procedure for detailed installation instructions).
c. Joint service connector to compressor. Use new 0-rings. Six small 0-rings and one large 0-ring are required.
d. Evaporator to compressor (suction) pipe, and new 0-ring.
e. Compressor to condenser (discharge) hose and new 0-ring.
f. Receiver/dryer and 0-ring.
R-134a amount: 550 grams (1.21 lb)
PAG oil amount: 100 cc (3.0 oz)
Parts Required:
Receiver/dryer - 91172080
Adapter, Low Side - 91172092
Adapter, High Side - 91172093
0-Rings:
Compressor - Small (6) - 91172095
Large - 96068915
Receiver/dryer (2) - 96068488
Suction hose - 96068490
Discharge hose - 96068489
Suction hose - 91172091
Discharge hose - 91172085