Dieseling/Run-on
DEFINITIONEngine continues to run after key is turned "OFF", but runs very roughly. If engine runs smoothly, check ignition switch and adjustment.
PRELIMINARY CHECKS
Refer to Preliminary Checks. - Important Preliminary Checks
FUEL SYSTEM
CHECK:
- Evaporative system and fuel tank venting.
- Fuel Injector for leakage. Refer to Diagnostic Charts / Chart A-6 Fuel System Diagnosis. Testing and Inspection