APP 3
Range 0-5 Volts:The PCM uses the APP sensors to control fuel delivery as requested by the driver. Three APP sensors are located in a module at the base of the accelerator pedal. The PCM only requires information from one sensor, the other two serve as fail safes. APP 3 should read about 4.0 volts at idle and steadily decrease to about 2.5 volts at wide open throttle.