Inadvertent Power Relay
The BCM turns off inadvertent power relay after 20 minutes (1216 seconds) to preserve battery power. The 20 minute timer starts after any one of the following:^ Ignition switch is turned from run or start to unlock, lock or ACC.
^ Illuminated entry is activated
^ Interior lamps switch is turned on
^ The liftgate is opened or closed
^ Underhood lamp is activated
^ Vanity lamp is activated
^ Courtesy lamp is activated
^ Dome lamp is activated
^ Glove box lamp is activated
^ Reading lamp is activated
^ Inside rearview mirror lamp is activated.
If any one of the below inputs occur during the 20 minute timer period, the timer is reset to 20 minutes (1216 seconds).
^ Ignition switch is turned from run or start to unlock, lock or ACC.
^ Illuminated entry is activated
^ Interior lamps switch is turned on
^ The liftgate is opened or closed
^ Courtesy lamp is activated
^ Dome lamp is activated