Operation CHARM: Car repair manuals for everyone.

Security Lamp State - Displays

ON/OFF/FLASHING: The security lamp will turn ON steady for 5 seconds and then turn OFF when the ignition switch is turned from the OFF position to the RUN position. The security telltale should have 3 states: OFF, ON steady, and FLASHING. The security telltale will stay ON steady (after the bulb check) if any DTC is stored in the EVO/PASSLOCK (TM) Module; it the EVO/PASSLOCK (TM) Module loses battery, ignition, or both while ignition is still supplied to the security lamp; or the security lamp driver is shorted to ground. The security telltale will flash for approximately 10 minutes to indicate that the PASSLOCK (TM) Module is in lockout Tamper mode during which the fuel delivery will be defaulted to Disable. The PASSLOCK (TM) system requires 3 consecutive lockout cycles to complete the 30 minute Auto Learn procedure for a changed component, refer to PASSLOCK Reprogramming Auto Learn to perform this task. Another option is the 10 minute Seed and Key procedure, refer to PASSLOCK Reprogramming Seed and Key Service and Repair to perform this task.