Blower Motor - Auxiliary (Front Auxiliary)
BLOWER MOTOR REPLACEMENT - AUXILIARY (FRONT AUXILIARY)
REMOVAL PROCEDURE
1. Remove the HVAC module-auxiliary assembly.
2. Disconnect the electrical connectors (4) from the blower motor-auxiliary (3).
3. Remove the air outlet duct from the blower motor-auxiliary.
4. Remove the screws (2,5) from the blower motor-auxiliary.
5. Remove the blower motor-auxiliary (3).
INSTALLATION PROCEDURE
1. Install the blower motor-auxiliary (3).
2. Install the retaining screws (2,5) to the blower motor-auxiliary.
Tighten the screws to 10 N.m (88 lb in).
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the air outlet duct to the blower motor-auxiliary.
4. Connect the electrical connectors (4) to the blower motor-auxiliary (3).
5. Install the HVAC module assembly.