Testing for Continuity
Testing for Continuity
Special Tools
EL-39200 - Digital Multimeter (DMM)
For equivalent regional tools, refer to Special Tools Tools and Equipment.
Caution: Refer to Test Probe Caution Test Probe Caution.
The following procedures verify good continuity in a circuit.
With a Digital Multimeter (DMM)
1. Set the DMM to the Ohms position.
2. Disconnect the power feed (i.e. fuse, control module) from the suspect circuit.
3. Disconnect the load.
4. Select the MIN MAX function on the DMM.
5. Connect one lead of the DMM to one end of the circuit to be tested.
6. Connect the other lead of the DMM to the other end of the circuit.
7. If the DMM displays low or no resistance, the circuit has good continuity.
With a Test Lamp
Note: Only use the test lamp procedure on low impedance power and ground circuits.
1. Remove the power feed (i.e. fuse, control module) from the suspect circuit.
2. Disconnect the load.
3. Connect one lead of the test lamp to one end of the circuit to be tested.
4. Connect the other lead of the test lamp to battery positive voltage.
5. Connect the other end of the circuit to ground.
6. If the test lamp illuminates (full intensity), then the circuit has good continuity.