Actuator Operation Check
1. Connect terminal 3 to battery positive terminal.2. Connect terminal 1 and 2 to negative terminal.
3. Apply vacuum to port of actuator, then check accelerator cable is held in a drawn in position.
4. Disconnect terminal 2 from battery negative terminal, then check accelerator cable connecting point moves to initial position.
5. Repeat step 4 for terminal 1.