Auto Shutdown (ASD) Sense
PURPOSE A 12 volt signal at this input indicates that the Automatic Shutdown
(ASD) relay has been activated.
OPERATION This input is used only to sense that the
ASD relay is energized. If the
Powertrain Control Module (PCM) does not see 12 volts when the ASD relay should be activated, it will set a Diagnostic Trouble code.