EVIC Switch Input Circuit Shorted
Test 1 - 2:
Test 3:
SYMPTOM
EVIC SWITCH INPUT CIRCUIT SHORT
WHEN MONITORED
The MIC power-up diagnostics will test the EVIC Button A/D port for either an open circuit, short to power or ground, or a stuck button exists.
SET CONDITION
This DTC will set when the Instrument Cluster detects excessive current on the EVIC MUX Signal circuit.
POSSIBLE CAUSES
- EVIC MUX signal circuit short to return circuit
- Instrument panel switch POD
- EVIC MUX signal circuit short to ground
- Instrument cluster