B220B

B220B-OCCUPANT RESTRAINT CONTROLLER FIRING STORED ENERGY

WHEN MONITORED
With the ignition on. The module's on board diagnostics continuously performs internal circuit tests.

SET CONDITION
This DTC will set if the module identifies an out of range internal circuit.

POSSIBLE CAUSES
- Occupant restraint controller

Diagnostic Test

1. REPLACE OCCUPANT RESTRAINT CONTROLLER

Turn the ignition on.

WARNING:
- TO AVOID PERSONAL INJURY OR DEATH, TURN THE IGNITION OFF, DISCONNECT THE BATTERY AND WAIT TWO MINUTES BEFORE PROCEEDING.
- IF THE OCCUPANT RESTRAINT CONTROLLER IS DROPPED AT ANY TIME, IT MUST BE REPLACED. FAILURE TO TAKE PROPER PRECAUTIONS CAN RESULT IN ACCIDENTAL AIRBAG DEPLOYMENT AND PERSONAL INJURY OR DEATH
.

Repair
Replace the Occupant Restraint Controller. Perform the AIRBAG SYSTEM VERIFICATION TEST - VER 1. Airbag System Verification Test