Operation CHARM: Car repair manuals for everyone.

Leak Testing







LEAK TESTING

WARNING: The normal operating temperature of the exhaust system is very high. Therefore, never work around or attempt to service any part of the exhaust system until it is cooled. Special care should be taken when working near the catalytic converter. The temperature of the converter rises to a high level after a short period of engine operation time.

1. Raise and support vehicle.

CAUTION: The air pressure must not exceed 4 psi, otherwise engine damage can occur.

2. Connect Tool 8404-EC or 8404-ECT, Exhaust Cone to an adjustable air pressure regulator.
3. Attach shop air to the air pressure regulator.
4. Adjust the air pressure regulator to 4 psi
5. Insert Tool 8404-EC or 8404-ECT, Exhaust Cone into the vehicle tail pipe.
6. If the vehicle is equipped with dual exhaust, use Tool 8404-EC or 8404-ECT, Exhaust Cone with equipped attached plug. Plug one side of the dual exhaust pipe. Pressurize the other as described.
7. Apply a mixture of liquid dish soap and water to the following areas:
- - All welded joints from 6 inches rearward of the downstream O2 sensor forward
- - O2 sensor seal points
- - O2 sensor boss welds
- - Flange/joint connection(s)
- - Exhaust manifold to cylinder head connection(s)
- - EGR solenoid gasket base and tube seal points (if equipped)

8. Watch for the liquid/soapy water to bubble.
9. Use the following definitions to help determine if system or component repair/replacement is necessary:
- Type 1 Leak is defined as a leak where very small foam like bubbles 1mm (.039 in.) or less appear. Any Type 1 or greater leaks found in welded joints, O2 sensor seal points or O2 sensor boss welds must be repaired or the component must be replaced.
- Type 2 Leak is defined as a leak where larger bubbles 8mm (.031 in.) or greater appear. Any Type 2 or greater leaks found in flange or joint connections, exhaust manifold to cylinder head connections, or EGR gasket and tube seal points must be repaired or the components must be replaced.






If a leak is found that matches the above definition, repair or replace the component as necessary.

Once the repair is complete, repeat the procedure to verify that all leaks have been repaired.