Blower Motor Resistor - Installation
INSTALLATION
1. Position the rear blower motor resistor (3) into the rear heater-A/C housing (1).
2. Install the two screws (4) that secure the rear blower motor resistor to the rear heater-A/C housing. Tighten the screws to 1.2 Nm (10 in. lbs.).
3. Connect the wire harness connector (2) to the rear blower motor resistor.
4. Position the rear heater-A/C housing (4) to the rear inner quarter panel.
5. Install the two bolts (5) that secure the rear heater-A/C housing to the two brackets (3) located on the rear inner quarter panel (1). Tighten the bolts to 3 Nm (27 in. lbs.).
6. Install the bolt (7) that secures the rear heater core tubes to the rear inner quarter panel. Tighten the bolt to 3 Nm (27 in. lbs.).
7. Install the rear ceiling distribution duct Air Outlet - Installation.
8. Install the rear floor distribution duct Floor Distribution Duct - Installation.
9. Connect the negative battery cable.