Instrument Cluster - Removal
REMOVAL - LHD
WARNING:
To avoid serious or fatal injury on vehicles equipped with airbags, disable the Supplemental Restraint System (SRS) before attempting any steering wheel, steering column, airbag, seat belt tensioner, impact sensor, or instrument panel component diagnosis or service. Disconnect and isolate the battery negative (ground) cable, then wait two minutes for the system capacitor to discharge before performing further diagnosis or service. This is the only sure way to disable the SRS. Failure to take the proper precautions could result in accidental airbag deployment.
CLUSTER ASSEMBLY
1. Disconnect and isolate the negative battery cable.
2. Remove the instrument panel top pad, Instrument Panel Pad - Removal.
3. Remove the screws that secure the instrument cluster (1) to the instrument panel.
4. Pull the instrument cluster forward far enough to access and disconnect the instrument panel wire harness connectors on the back of the cluster housing.
5. Remove the instrument cluster from the instrument panel.
CLUSTER LENS, HOOD AND MASK
1. Remove the instrument cluster assembly from the instrument panel.
2. Working around the perimeter of the cluster, disengage each of the integral latch features that secure the top and sides of the cluster lens, hood and mask unit to the cluster housing.
3. Separate the lens, hood and mask unit from the cluster and remove.