Wiring Harness/Connectors
The connector for the sensing and diagnostic module (SDM) has a built-in shorting bar that will turn on the warning lamp if there is a poor connection at the SDM. As an anti-deployment mechanism, additional shorting bars are in the:- Connector for the clock spring at the lower steering column.
- Passenger airbag module connector.
- SDM connector.
When these connectors are separated, the shorting bars will short circuit any current which is applied, preventing the current from reaching the airbag modules.