Distributor Shaft & Bushing Wear Test
1. Remove distributor from vehicle and clamp distributor in a vise. Use extreme caution not to damage distributor.
2. Attach a dial indicator to housing so plunger rests against reluctor sleeve.
3. Place a wire loop around reluctor sleeve and hook a spring scale on the other end of the loop. Apply a 1-1/2 lb. pull toward dial indicator. Apply a 1 lb. pull away from dial indicator and read movement on indicator.