Mixture Control Solenoid: Testing and Inspection
Carburetor Components:
To test the Feedback Solenoid Valve, located in the float bowl of the carburetor, proceed as follows.
1. Disconnect the wiring harness connector (connector M-21).
Feedback Solenoid Valve Test:
2. Apply battery voltage (approximately 12 Volts) between terminals 4 and 5 on the FBSV.
3. If the solenoid valve does not actuate with an audible click, replace the solenoid.
Feedback Solenoid Valve Resistance Test:
4. Measure the resistance between the terminals of the solenoid valve.
5. If the resistance is not between 54 and 66 ohms, at 68° F, replace the solenoid valve.