Input Shaft End Play Check
NOTE: Overdrive unit must be installed in order to correctly measure the input shaft end-play.1. Check input shaft end play as follows.
2. Attach dial indicator to converter housing. Position indicator plunger against input shaft and zero indicator.
3. Move input shaft in and out and record reading.
4. End play should be 0.86 - 2.13 mm (0.034 0.084 inch).
5. If end play is incorrect, change intermediate shaft thrust washer. The thrust washer controls end play and is available in three thicknesses for adjustment purposes.