Neutral Safety Switch: Testing and Inspection
- In the START position, the ignition switch connects circuit A1 from the Power Distribution Center (PDC) to circuit A41. A 30 amp maxi fuse in cavity 7 of the fuse block protects circuits A1 and A41.- The [1][2]Park/Neutral position switch and back-up lamp switch are molded together.