Extension Housing and Park Lock
Clean the housing and park lock components in solvent and dry them with compressed air.Examine the park lock components in the housing. If replacement is necessary, remove the shaft with parallel jaw snap ring pliers and remove the sprag and spring. Then remove the spring clip and reaction plug. Compress the reaction plug spring clip only enough to remove and install it. Do not distort the clip during removal or installation.