Procedure A
1. Disengage the latch and keeper.2. Remove latch and keeper screws.
3. Separate latch and keeper from glass panel.
4. Position new latch and keeper (from package p/n 04773094) onto the glass panels.
5. Secure the latch and keeper with the new screws that came with package p/n 04773094 and tighten the screws to 1.5 N.m (15 in. lbs.).