Cleaning and Inspection
CLEANINGClean mating surfaces on cylinder head and manifold. Wash with solvent and blow dry with compressed air.
INSPECTION
Inspect manifold for cracks.
Inspect mating surfaces of manifold for flatness with a straight edge. Gasket surfaces must be flat within 0.2 mm per 300 mm (0.008 inch per foot).