Door Lock Switch Failure (PDL)
Test 416 - 419:
SYMPTOM
DOOR LOCK SWITCH FAILURE (PDL)
WHEN MONITORED
Continuously
SET CONDITION
If the door lock switch is active for more than 30 seconds.
POSSIBLE CAUSES
- Right door lock switch defective
- Left door lock switch defective
- Door lock switch input CKT short to battery
- Central module timer defective