Operation CHARM: Car repair manuals for everyone.

Door Unlock Switch Failure (PDL)

Test 400 - 403:




SYMPTOM
DOOR UNLOCK SWITCH FAILURE (PDL)

WHEN MONITORED
Continuously

SET CONDITION
If the door unlock switch is active for more than 30 seconds.

POSSIBLE CAUSES
- Right door lock switch defective
- Left door lock switch defective
- Door unlock switch input CKT short to battery