Passenger Squib Shorted to Ground With On/Off Switch (Active)
Test 1:
Test 2 - 4:
Test 5 - 7:
SYMPTOM
PASSENGER SQUIB SHORT TO GROUND W/ ON/OFF SWITCH (ACTIVE)
WHEN MONITORED
Continuously with the ignition ON.
SET CONDITION
The ACM has detected a short to ground in the Passenger Squib circuits.
POSSIBLE CAUSES
- ON/OFF switch, passenger airbag line 1 or line 2 shorted to ground
- DTC active with PAB in OFF position only
- Passenger airbag module circuits shorted to ground
- Passenger airbag line 1 shorted to ground
- Passenger airbag line 2 shorted to ground
- PAB line 1 or line 2 circuits shorted to ground between ON/OFF switch and PAB
- ACM, PAB circuit shorted to ground