Cylinder Lock Switch Failure/Lock
Test 1 - 3:
Test 4 - 6:
SYMPTOM
CYLINDER LOCK SWITCH FAILURE/LOCK
WHEN MONITORED
Continuously
SET CONDITION
If the CTM detects that the Cylinder Lock switch remains in the "lock" position longer then 30 seconds.
POSSIBLE CAUSES
- Defective driver lock switch
- Door key cylinder mechanical malfunction
- Defective passenger lock switch
- Cylinder lock switch MUX circuit short to ground
- Defective CTM - lock