P1765 (80) - Switched Battery
Name of Code:P1765 (80) - Switched Battery
When Monitored:
Ignition key is turned from "off' position to "run" position and/or ignition key is turned from "crank" position to "run" position.
Set Condition:
This code is set if the Transmission Control Module (TCM) senses voltage on any of the pressure switch inputs prior to the TCM energizing the relay.
Theory of operation:
The Transmission control relay is used to supply power to the solenoids and pressure switches when the transmission is in normal operating mode. When the relay is off, no power is supplied and the transmission is in "limp-in" mode. The relay output is fed back to the TCM through pins 16, 17 and 38. It is referred to as "Transmission Control Relay Output".
Immediately after a controller reset (ignition key turned to the "run" position or after cranking engine), the TCM verifies that the relay contacts are open by checking for no voltage at the transmission control relay output terminals. After this is verified, the voltage at the pressure switches is checked. There should be no voltage on the pressure switches at this time. The TCM will then activate the relay.
Transmission Effects:
The MIL will illuminate and the transmission system will default to the Immediate Shutdown routine.
Possible causes:
- Short to battery on one or more pressure switch sense circuits.
- TCM connector problems.
- Solenoid/TRS connector problems.
- TCM.