Right Front Turn Signal Output Open
Tests 1 - 2:
Tests 3 - 6:
SYMPTOM
RIGHT FRONT TURN SIGNAL OUTPUT OPEN
WHEN MONITORED
Ignition ON.
SET CONDITION
When the output voltage status is LOW.
POSSIBLE CAUSES
- Intermittent condition
- Ground circuit
- Turn signal lamp
- Right front turn signal output circuit open
- Right front turn signal driver circuit open
- Body control module
- Intelligent power module