All Gauges Inoperative
Tests 1 - 4:
Tests 5 - 6:
SYMPTOM
ALL GAUGES NOT OPERATING
POSSIBLE CAUSES
- No response - PCI bus
- No response - PCI bus instrument cluster
- NO RESPONSE - PCI bus powertrain control module
- Fused ignition switch output circuit short to ground
- Ground circuit open
- Fused B+ ignition switch output circuit open
- Instrument cluster