Driver Squib 1 Circuit Open
Test 1:
Tests 2 - 4:
Test 5:
SYMPTOM
DRIVER SQUIB 1 CIRCUIT OPEN
WHEN MONITORED
With the ignition ON the ACM monitors the resistance of the Driver Squib 1 circuits.
SET CONDITION
The ACM detects an open circuit or high resistance in the Driver Squib 1 circuits.
POSSIBLE CAUSES
- Driver airbag open
- Clockspring squib circuits open
- Driver Squib 1 line 1 or line 2 circuit open
- ACM, Driver Squib 1 circuit open
- Stored code or intermittent condition
- Active code present