Right B-Pillar Switch Input Stuck
Tests 1 - 3:
SYMPTOM
RIGHT B-PILLAR SWITCH INPUT STUCK
WHEN MONITORED
Continuously when the BCM is awake.
SET CONDITION
When the BCM senses an active switch input for over 10 seconds.
POSSIBLE CAUSES
- DTC present
- Right B-pillar switch shorted
- Right sliding door pillar switch MUX wire short to ground
- Body control module - right sliding door pillar switch circuit shorted