Passenger SBS Shorted to Battery
Tests 1 - 2:
Tests 3 - 4:
SYMPTOM
PASSENGER SEAT BELT SWITCH SHORT TO BATTERY
WHEN MONITORED
The ORC monitors the Seat Belt Switch circuit for an short to battery.
SET CONDITION
The code will set if the ORC detects high circuit voltage.
POSSIBLE CAUSES
- Passenger SBS short to battery
- Passenger seat belt switch circuits shorted to battery
- ACM, passenger seat belt switch short to battery
- Stored code or intermittent condition
- Active code present